VTFN300-Flow Switch With LED Digital Display

Measuring range
Water 1…200cm/s(The default display value is calibrated with water, other media need to be specified)
Oil 3…300cm/s
Air 20…2000cm/s
Measuring medium Water, oil, gas and other media compatible with stainless steel
Repeatability 1%@<0.6m/s; 3%@<1.5m/s; 10%@>1.5m/s
Withstand voltage 100bar
Initialization time 1…8s
Response time Typical value2s.
Supply voltage 18…30Vdc
No-load current consumption ≤500mA,exist24VdcWhen power supply
Switch output
Output type Push-pull (compatible withPNPandNPN), normally open and normally closed can be set
S1,S2Output current <500mA
Voltagedrop <1V
Current mode analog output
Output classtype Third line0…20mA/4…20mACan be set
LoadRA RA≤0.5KΩ
Wiring protection Reverse phase, overload, short circuit protection
Show
Design Red4 bit8mm high brightnessled
Display range -1999…9999
Temperature
Operating temperature -40…85℃
Medium temperature -20…85℃
Material
Shell Stainless steel304
Probe Stainless steel304
Degree of protection IP67
Outgoing way M12×1Connector
Category: Tag:

Based on the thermodynamic principle, VTFN300 features 2 temperature sensors inside the probe: onefor medium temperature, the other one is heated a few degrees up compared to the medium into which it projects.When the medium flows, the heat generated in the sensor is conducted by the medium. The difference between these two sensors can be measured to get the flow rate. Compared to traditional products, FN3000 offers a wider measuring range, less temperature drifting, and percentage or flow velocity display. All metal housing.highlighted digital LED, dual-key and user-friendly interface, and multiple process connections.330° rotatable indicator.

 

Applications

Hydraulic /Lubrication

Pump protection

Cooling water monitoring

Ventilation system

Machinery manufacture

Water treatment