VTFM100-Electromagnetic Flow Meters

 

Applicable medium Conductivity>5us/cmliquid (demineralized water is20us/cm)
Measuring range 0.25…10m/s
Applicable pipe diameter DN25…DN500
Accuracy ±0.5%read value (±0.2%optional)
Repeatability ±0.15Measurements
Operating Voltage 18-36VDC
Output signal Electric current:4…20mA
Pulse: Frequency0…1KHz
Work pressure DN10…DN65:≤2.5Mpa
DN80…DN150:≤1.6Mpa
DN200…DN500: ≤1.0Mpa(Special specifications can be customized)
Electrode material 316L
Lining material NeopreneCR
PTFEF4
Housing and flange material Carbon steel (standard)
Excitation method Three-amplitude low-frequency rectangular wave excitation and high-frequency excitation
Medium temperature -20℃…90℃…130℃…180℃(Refer to lining material)
Ambient temperature Sensor-40℃…80°C; Converter-15℃…60℃
Environment humidity ≤85%RH (20°C)
Power consumption Less than20W
Structure type One-piece, clip-on
Electrical Interface M12X1.5
Grounding method With grounding ring
Explosion-proof level Exd ib IIBT4
Connection method Flange connection
Degree of protection IP65

 

Category: Tag:
VTFM100 electromagnetic flowmeter is designed based on Faraday’s law of electromagnetic induction: When the conductive liquid cuts the magnetic force in the magnetic field, the conductive potential is generated in the conductor. When the flow rate is measured, the conductive liquid flows through the magnetic field perpendicular to the flow direction at the speed of V. The conductive liquid flow induces a voltage that is proportional to the average flow rate. And through the cable to the converter through intelligent processing, to achieve the instantaneous fluid flow, accumulated flow display and flow data and communication between the control system.
Applications
Tap water supply field
Industrial wastewater field
Strong acid liquid industrial field
Food industry
Paper industry

Reviews

There are no reviews yet.

Be the first to review “VTFM100-Electromagnetic Flow Meters”